- Baldor-Reliance Super-E: NEMA Premium efficiency, inverter ready, 3-year warranty
- TEFC 10–200 HP and ODP 10–150 HP at 3600, 1800 and 1200 RPM
- 230/460V standard; "-4" models are 460V only; 575V (-5) and 200V (-8) versions available
- Old U-frame motor? We match it to the current T-frame Super-E
TEFC (totally enclosed fan-cooled)
For dirty, wet or outdoor locations. Catalog number · NEMA frame. A "TS" frame is a short shaft for direct-coupled 2-pole applications.
| HP | 3600 RPM (2-pole) | 1800 RPM (4-pole) | 1200 RPM (6-pole) |
|---|---|---|---|
| 10 | EM3711T · 215T | EM3714T · 215T | EM2332T · 256T |
| 15 | EM2394T · 254T | EM2333T · 254T | EM4100T · 284T |
| 20 | EM4106T · 256T | EM2334T · 256T | EM4102T · 286T |
| 25 | EM4107T · 284TS | EM4103T · 284T | EM4111T · 324T |
| 30 | EM4108T · 286TS | EM4104T · 286T | EM4117T · 326T |
| 40 | EM4109T · 324TS | EM4110T · 324T | EM4308T · 364T |
| 50 | EM4114T · 326TS | EM4115T · 326T | EM4312T · 365T |
| 60 | EM4310T · 364TS | EM4314T · 364T | EM4403T · 404T |
| 75 | EM4313T · 365TS | EM4316T · 365T | EM4404T · 405T |
| 100 | EM4402T-4 · 405TS | EM4400T · 405T | EM4409T-4 · 444T |
| 125 | EM4412T-4 · 444TS | EM4410T-4 · 444T | EM4411T-4 · 445T |
| 150 | EM4413T-4 · 445TS | EM4406T-4 · 445T | EM44156T-4 · 447T |
| 200 | EM4416T-4 · 447TS | EM4407T-4 · 447T | EM44206T-4 · 449T |
ODP (open drip-proof)
For clean, dry indoor locations: fans, pumps and compressors in mechanical rooms.
| HP | 3600 RPM (2-pole) | 1800 RPM (4-pole) | 1200 RPM (6-pole) |
|---|---|---|---|
| 10 | EM3312T · 213T | EM3313T · 215T | EM2511T · 256T |
| 15 | EM3314T · 215T | EM2513T · 254T | EM2524T · 284T |
| 20 | EM2514T · 254T | EM2515T · 256T | EM2528T · 286T |
| 25 | EM2516T · 256T | EM2531T · 284T | EM2532T · 324T |
| 30 | EM2534T · 284TS | EM2535T · 286T | EM2536T · 326T |
| 40 | EM2538T · 286TS | EM2539T · 324T | EM2540T · 364T |
| 50 | EM2542T · 324TS | EM2543T · 326T | ask us |
| 60 | ask us | EM2547T · 364T | ask us |
| 75 | ask us | EM2551T · 365T | ask us |
| 100 | ask us | EM2555T · 404T | ask us |
| 125 | ask us | EM2559T-4 · 405T | ask us |
| 150 | ask us | EM2558T-4 · 444T | ask us |
Replacing an old U-frame motor
Motors built before the mid-1960s use larger U frames. Baldor still lists U-frame motors, or we can match a T-frame motor with an adapter base.
| Catalog number | HP | RPM | Frame | |
|---|---|---|---|---|
| M2393 | 10 | 3600 | 254U | Quote → |
| M2238 | 10 | 1800 | 256U | Quote → |
| M2332 | 10 | 1200 | 284U | Quote → |
| M2394 | 15 | 3600 | 256U | Quote → |
| M2333 | 15 | 1800 | 284U | Quote → |
| M2334 | 20 | 1800 | 286U | Quote → |
| M4106 | 20 | 3600 | 286U | Quote → |
| M4103 | 25 | 1800 | 324U | Quote → |
| M4107 | 25 | 3600 | 324U | Quote → |
| M4104 | 30 | 1800 | 326U | Quote → |
Suffixes you'll see
- -4: 460V only. -5: 575V. -8: 200V
- -G: AEGIS shaft grounding ring, for motors on a VFD
- C prefix (CEM...): C-face mounting
From Baldor-Reliance's general purpose motor listings. Confirm frame, shaft and mounting against your nameplate; we verify before quoting. Need crusher duty instead? See Baldor crusher duty motors.
Common questions
Which catalog number do I need?
Find your HP and speed in the TEFC or ODP table. If your old motor is a different brand, use our equivalent finder in the catalog or send the nameplate.
TEFC or ODP?
TEFC for dusty, wet or outdoor locations. ODP for clean, dry indoor spaces. Match your existing motor unless the environment has changed.
Can these run on a VFD?
Super-E motors are inverter ready. For VFD use we can quote the -G version with a shaft grounding ring.