Verified specifications
| Horsepower | 25 HP |
|---|---|
| Speed | 1180 RPM |
| Voltage | 230/460V, three-phase, 60 Hz |
| Frame | 324T, iron |
| Enclosure | TEFC |
| Full-load amps | 64/32A (70A @208V) |
| Efficiency | 93.0% |
| Service factor | 1.15 |
| Code letter | H |
| NEMA design | A |
| Power factor | 79 |
| Insulation | Class F |
| Shaft | 2.125" |
| Bearings | 6312 / 6309 |
| Weight | 494 lb ship |
| Locked-rotor amps | 220A @460V |
| Inverter rated | Yes |
| NEMA Premium | Yes |
Confirming the right replacement
Before we quote, compare these fields on your failed motor's nameplate. If any of them differ, send us a photo of the nameplate and we'll match it exactly rather than guessing:
- Full model number — including any suffix letters
- HP, RPM, and voltage
- Frame size (e.g. 284T) and enclosure (TEFC, ODP, etc.)
- Full-load amps
Other Baldor models
- More Baldor modelsBrowse every Baldor model page we quote
- Baldor EM2332T10 HP, 1200 RPM, 256T TEFC
- Baldor EM4100T15 HP, 1200 RPM, 284T TEFC
Need a Baldor EM4111T?
Send the nameplate off your failed unit. We'll confirm the match and quote the EM4111T or a verified equivalent with availability and lead time.