Verified specifications
| Horsepower | 1/40 HP |
|---|---|
| Speed | 3250 RPM, single-speed |
| Voltage | 115V, single-phase, 60 Hz |
| Amps | 1.30A |
| Max power | 140W |
| Flow range | 0–33 GPM |
| Head range | 0–21 ft |
| Connection | Flanged, 8-1/2" port-to-port (F3) |
| Body | Cast iron |
| Liquid temperature | 40–220°F |
| Max working pressure | 125 psi |
Every 00-series (“double-oh”) circulator uses Taco's replaceable cartridge — the cartridge holds all the moving parts, so a failed unit can often be repaired with a cartridge swap instead of a full replacement. Cast iron = closed-loop heating only; stainless/bronze = potable water.
F3 vs F5: the F3 flange is 8-1/2" port-to-port; the F5 is 6-3/8" — measure before quoting. Fan-coil and booster duty.
Confirming the right replacement
Before we quote, compare these fields on your failed pump's nameplate. If any of them differ, send us a photo of the nameplate and we'll match it exactly rather than guessing:
- Full model number — including the part number (e.g. B&G P/N) where one exists
- Voltage and phase
- System duty: flow (GPM), head (ft), and fluid — heating water vs. potable water matters
- Flange size and orientation for in-line replacements
Other Taco models
- More Taco modelsBrowse every Taco model page we quote
- Taco 007-F5007 cartridge circulator, 1/25 HP
- Taco 009-F5009 high-head cartridge circulator, 1/8 HP
- Taco 0010-F30010 high-flow cartridge circulator, 1/8 HP
Documented equivalent replacements
The motors below are published as replacements for this model in the cross-reference tables cited. We confirm the match against your nameplate before quoting:
| Documented equivalent | Cross-reference source |
|---|---|
| Grundfos UPS 26-99 FC (high speed) | Grundfos-published cross reference (manufacturer) |
Cross references via Grundfos-published cross reference documents (VersaFlo UPS/TP guide L-UP-TL-008 and the competitive 3-speed pump cross reference). Match flange size, head, and flow to your system before ordering.
Need a Taco 0013-F3?
Send the nameplate off your failed unit. We'll confirm the match and quote the 0013-F3 or a verified equivalent with availability and lead time.
Quote this pump