Verified specifications
| Horsepower | ECM variable-speed |
|---|---|
| Speed | 1590–4830 RPM |
| Voltage | 120V, single-phase, 60 Hz |
| Amps | 0.54A |
| Watts | 44W max |
| Body | Composite — open-loop potable OK (per MFR: open-loop potable + closed hydronic) |
| Connections | 1" union (fittings sold separately: UFS-050S/T/P, UFS-075S/T/P) |
| Max flow | 11 GPM |
| Max head | 13 ft |
| Max pressure | 150 psi |
| Temperature range | 36–203°F |
| Duty | ECM recirculation — DHW recirc and small closed hydronic; NOT for chilled water |
The dial is premarked with 003 & 006 performance points — this is the ECM upgrade for the 003/006 pages. 006e3LC variant includes a 6' power cord (006e3 = VM1212-DY1-UP2A00, 006e3LC = VM1212-DY1-UP2A01).
Confirming the right replacement
Before we quote, compare these fields on your failed pump's nameplate. If any of them differ, send us a photo of the nameplate and we'll match it exactly rather than guessing:
- Full model number — including the part number (e.g. B&G P/N) where one exists
- Voltage and phase
- System duty: flow (GPM), head (ft), and fluid — heating water vs. potable water matters
- Flange size and orientation for in-line replacements
Other Taco models
Need a Taco 006e3?
Send the nameplate off your failed unit. We'll confirm the match and quote the 006e3 or a verified equivalent with availability and lead time.
Quote this pump