Verified specifications
| Horsepower | 1/20 HP |
|---|---|
| Speed | Variable-speed ECM |
| Voltage | 230V, single-phase, 60 Hz |
| Amps | 1.15A |
| Flow range | 0–34 GPM |
| Head range | 0–19 ft |
| Connection | Flanged, 6-3/8" port-to-port |
| Flow check | Integral |
| Product line | 00R series ECM circulator |
Every 00-series (“double-oh”) circulator uses Taco's replaceable cartridge — the cartridge holds all the moving parts, so a failed unit can often be repaired with a cartridge swap instead of a full replacement. Cast iron = closed-loop heating only; stainless/bronze = potable water.
00R series: replaces the 00R-MSF6-1 and 00R-MSF6-2. The 00R-MS1-2P is a different, discontinued pump — not the same.
115V version: see the VR3452-HY1-FC1A01.
Confirming the right replacement
Before we quote, compare these fields on your failed pump's nameplate. If any of them differ, send us a photo of the nameplate and we'll match it exactly rather than guessing:
- Full model number — including the part number (e.g. B&G P/N) where one exists
- Voltage and phase
- System duty: flow (GPM), head (ft), and fluid — heating water vs. potable water matters
- Flange size and orientation for in-line replacements
Other Taco models
Need a Taco VR3452-HB1-FC1A01?
Send the nameplate off your failed unit. We'll confirm the match and quote the VR3452-HB1-FC1A01 or a verified equivalent with availability and lead time.